- Contact Person : Mr. YANG Lei
- Company Name : Wuxi Hu An Electric Wire And Cable Co., Ltd.
- Tel : 86-510-87219215
- Fax : 86-510-87205602
- Address : Jiangsu,Yixing,Donghong Rd 6. Guanlin Town Yixing City,Jiangsu Province,China
- Country/Region : China
aluminium and steel reinforced conductor, XLPE insulated aerial cable
1.Standard
The products comply with the standards GB12527-90 and GB14049-93
2. Example
Type | Name | Section Area(mm2) | No. of core |
JKV | Copper conducor, PVC insulated aerial bundled cable | 10-300 | 1, 3 |
10-240 | 1, 2, 3, 4 | ||
JKLV | Aluminium conductor, PVC insulated aerial bundled cable | 10-300 | 1, 3 |
10-240 | 1, 2, 3, 4 | ||
JKY | Copper conducor, PE insulated aerial bundled cable | 10-300 | 1, 3 |
10-240 | 1, 2, 3, 4 | ||
JKLY | Aluminium conductor, PE insulated aerial bundled cable | 10-300 | 1, 3 |
10-240 | 1, 2, 3, 4 | ||
JKYJ | Copper conductor, XLPE insulated aerial bundled cable | 10-300 | 1, 3 |
10-240 | 1, 2, 3, 4 | ||
JKLYJ | Aluminium conductor, XLPE insulated aerial bundled cable | 10-300 | 1, 3 |
10-240 | 1, 2, 3, 4 | ||
JKLY/Q | Aluminium conductor, PE thin-insulated aerial bundled cable | 10-300 | 1, 3 |
10-240 | 1, 2, 3, 4 | ||
JKLYJ/Q | Copper conductor, XLPE thin-insulated aerial bundled cable | 10-300 | 1, 3 |
10-240 | 1, 2, 3, 4 | ||
JKLGYJ | Aluminium and steel reinforced conductor, XLPE insulated aerial bundled cable | 10-300 | 1, 3 |
10-240 | 1, 2, 3, 4 |
Note: Section Area and No. of Core is divided by rated voltage that is 10KV, 35KV and 0.6/1KV
3.Scope of Application
Aerial bundled cable(ABC)is a novel concept for overhead power distribution. It is ideal for transmitting line and distributing line in street lighting, outdoor lighting, temporary service for construction and fit for hilly area, forest area etc.
4. Service Condition
(1)The long-time working temperature of conductor of PVC insulated cable is 70oC
The long-time working temperature of conductor of PE insulated cable is 70oC
The long-time working temperature of conductor of XLPE insulated cable is 90oC
(2) The Max. Temperature of cable under short-circuit (at most 5 seconds)
PVC insulatin:160 oC
PE insulatin:130oC
PVC insulatin:250 oC
(3) The temperature for laying the cables can not be lower than -20 oC
The temperature of operating ambient is -40~40 oC
5. Main Characteristic
ABC provide higher safety & reliability, less power loss, and lower installation, maintenance and operating costs.
aluminium and steel reinforced conductor, XLPE insulated aerial cable